Smart Watch SKMEI SMART 1283 operation guide

Smart Watch SKMEI SMART 1283 operation guide

Smart Watch SKMEI SMART 1283 operation guide

    Руководство / инструкция




    SKMEI SMART 1283 MOVEMENT INSTRUCTION

    SKMEI 1283 user manual

    Display and controls

    SKMEI 1283 user manual

    A. Features

    SKMEI 1283 user manual

    ➠ 13 Digits LCD Display, Display Hour, Minute, Second, Month, Day,Year and Week
    ➠ Automatic Calendar(2000~2099)
    ➠ Dual Time
    ➠ 12 / 24H format selectable, Auto Calendar
    ➠ Daily Alarm ,Chime hourly and SNZ
    ➠ 1/100 second to 23 hour 59.99 second Chronograph with split functions,12 groups of LAP segment timing
    ➠ Countdown function
    ➠ EL backlight
    ➠ Touch-tone

    B. Operational Manual

    SKMEI 1283 user manual

    1. At any mode, press A key EL backlight for 3s.

    2. Press B to change the display mode

    3. In real time mode press D key to switch 12 hours or 24 hours display.

    4. Real Time and date

    ☞ Time Setting
    a). Press and hold C key for 2s to time setting mode and "Second" flashing, Press B key to select item as following sequence:

    SKMEI 1283 user manual

    b) Press D key while the seconds are in the range of 30 to 59, resetting them to 00 and adding 1 to the minutes .While the seconds are in the range of 00 to 29, the minutes won’t be changed.
    c) Press D key to adjust the value increment, hold down D key to quickly adjust.
    d) Press C key to return to Real Time Mode.
    e) In setting mode. 1 minute No key operation automatically exit setting, return to real time display mode.

    .

    5. Dual Time Mode

    ☞ In the real time mode , Press B key 3 times to enter Dual Time Mode, Press and hold C key for 2s to select " Hour " setting, Press B key to select " Minute " setting,

    SKMEI 1283 user manual Dual Time Mode

    ☞ Press D key to adjust the value increment, hold down D key to quickly adjust.
    ☞ Press C key again to finish setting ,and return to Dual Time displaying mode.
    ☞ In setting mode. 1 minute No key operation automatically exit setting, return to Dual Time displaying mode.
    ☞ The second of Dual Time is the same as real time.


    ..

    6. Daily Alarm

    ☞ Turn On / Off Alarm, Chime and Snooze
    a) In Alarm mode, press D and then Press C key to turn on/off Alarm ( ),
    b) In Alarm Mode, press C to turn on/offhourly chime (🔔) and snooze( “SNZ”),

    SKMEI 1283 user manual

    Alarm Mode:

    ☞ In alarm mode, press and hold C key for 2 seconds to enter the alarm time setting state, then press B key to select the setting items as follows:

    SKMEI 1283 user manual

    ☞ Press D key to adjust the value increment, hold down D key to quickly adjust.
    ☞ Press C key to return to Alarm Mode.
    ☞ In setting mode. No any key operation then will back to alarm display mode automatically after 1 minute.

    Remarks:

    * When you need a daily alarm, do not enter a number at the bottom ofthe screen. Please set it to "- - - -".

    * When you need a specify month alarm, you need to enter the number "12- - -" at the bottom of the screen.

    * When you need a specify day alarm, you need to enter the number "- - - 30" on the bottom of the screen.

    * When you need a specify date alarm, you need to enter the number, such as "12-30" at the bottom ofthe screen.

    * When Alarm is ON, the BB-BB - ring sounds for 10 seconds, the alarm when the screen symbol "" flashing, press any key to stop.

    Snooze function:

    ☞ In the Snooze function, The symbol "SNZ" is still flashing on the screen when the alarm stopped, snooze rings every 5minutes,total ring 6 times.
    ☞ When the snooze is ringing, press any key is to stop all the after snooze function.

    7. Chronograph mode

    ☞ The measurement range of chronograph is 23 hours 59 minutes 59.99 seconds, when reach the maximum, the chronograph re-count from "0"
    ☞ Chronograph LAP segment timing can remember 12 groups



    When running the Chronograph:

    ☞ Press D key to Start/Stop running; When stop, press C key to zero.
    ☞ When running, press C key to split counting. Press C key again to next LAP split counting.
    ☞ In the split counting, press D key to stop counting. Press C key to view the memory mode, press C key again to continue to view the next memory.
    ☞ When exit split count, hold on C key for 2 seconds to zero.
    ☞ When running, press B key to return to Real Time mode, and it runs at back.

    SKMEI 1283 user manual

    8. Countdown mode

    ☞ The display range ofthe timer is 1 minute to 23 hour 59 minute.

    In the countdown mode

    ☞ Press and hold C key for 2s to time setting mode and "Seconds" flashes. Press B key to select "Hour" , then Press B key "Minute" setting.

    SKMEI 1283 user manual

    ☞ Press D key to adjust the value increment, hold down D key to quickly adjust.
    ☞ Press C key to confirm, press B key return to the real time mode.
    ☞ In setting mode. No any key operation then will back to countdown mode automatically after 1 minute.
    ☞ Press D key to Start/Stop counting. Press C key for 2s to starting value when stop counting. Press C key for 2s again back to the setting mode.

    SKMEI 1283 user manual

    ☞ When the countdown stop to zero, the BB-BB - ring sounds for 15 seconds, press any key to stop the ring, when the ring stop, the countdown time will automatically return to the initial setting time.

    C. Specifications SKMEI 1283

     ➠ Module Size    : ø 37.2mm ➠ Module Thickness include buzzer : 9.2mm ➠ Operational Temperature Range  : -10°С~+60°С ➠ Operational Voltage   : 3.0V ➠ Accuracy    : ± 45sec/month ➠ Battery Code    : CR2025(capacitance: 170m Ah) ➠ static average current  : ≤1.5u A (static maximum current : 3.5 u A) ➠ Alarm average current   : ≤2m A Alarm maximum current : 5.0m A) ➠ EL lighten average current  : ≤8m A EL lighten maximum current : 10m A) ➠ Battery life (85%)   : ≥36 month (Japan Lithium) 

    Battery life calculate according to EL lighten four times each day for 3 seconds each time, alarm for 60 seconds each day

    Другие инструкции: